SolarEdge P505 Power Optimizer, 1.2m cable

SolarEdge P505 Power Optimizer, 1.2m cable

4,077 ₴
Generators
Sunday 11:53
Україна
вул. Стеценка, 14/44
19 views
Published 4 days ago by Solar-Tech
4,077 ₴
In Generators category
вул. Стеценка, 14/44, Київ, Україна
Get directions →
19 item views

SolarEdge P505 power optimizer is a specialized device designed to increase the output of photovoltaic panels. The optimizer tracks the maximum power point, increasing the energy output from photo modules by 25%. Another function of the optimizers is to monitor the photovoltaic system, collecting and transmitting data for monitoring. The device is installed on each panel or on two panels – this allows detailed control of each panel's production individually. The optimizers are equipped with the SafeDC feature, which automatically disconnects the DC voltage from the modules in case the grid power is lost or the inverter is turned off. Optimizers are compatible with c-Si and all thin-film photo-modules.

Main advantages of SolarEdge power optimizers:

-
Mitigates all losses related to module mismatch, from manufacturing tolerance to partial shading;

-
reduces system cost (50% fewer cables, fuses, and combiner boxes);

-
can be used with two photovoltaic modules connected in series or parallel (optimizer P600, P700);

-
flexible design system for maximum use of space;

-
quick installation with a single bolt;

-
module-level voltage shutdown for safety during installation;

-
module-level energy optimization;

-
high efficiency (99.5% maximum efficiency, 98.8% weighted efficiency);

-
designed to operate in extreme environmental conditions;

-
real-time performance measurements;

-
optimize module-level voltage increasing energy production by 25%;

-
allows mounting solar panels in locations with different solar insolation during the day;

-
SolarEdge power optimizers are compatible with c-Si and thin-film modules and carry a 25-year warranty.

Important!

-
The module's rated power at STC must not exceed the optimizer's "Rated DC input power." Modules with a power tolerance up to +5% are allowed.

-
For other connector types, contact SolarEdge

-
For the dual version for parallel connection of two modules use P485. When there is an odd number of photovoltaic modules in a string, it is supported to install one dual-version P485 power optimizer connected to a single photovoltaic module. When connecting one module, seal the unused input connectors with the pair of seals included in the delivery kit.

-
For ambient temperature above +70°C/+158°F a power derating applies. For more information refer to the temperature derating technical note.

-
Mixing P404/P485/P505/P601 with P370/P401/P500 in one string is not allowed

-
P370/P401/P500 cannot be used with the three-phase inverter SE3K (available in some countries; refer to the SE3K-SE10K three-phase inverter datasheet table)

-
Exactly 10 when using SE3K-RW010BNN4

-
If the inverters' AC rated power ≤ the largest rated power over time, the largest power over time may reach the inverters' maximum DC input power. See: https://www.solaredge.com/sites/default /files/se-power-optimizer-single-string-design-application-note.pdf

-
For 230/400 V network: up to 13,500 W per string is allowed if the maximum power difference between each limb is 2,000 W.

-
For 277/480 V network: up to 15,000 W per string is allowed if the maximum power difference between each limb is 2,000 W.

Technical specifications:

Power optimizer

SolarEdge P505

Rated module power compatible with the model, (W)

up to 505

Maximum input current, (A)

14

Maximum input voltage, (V)

83

MPPT voltage range, (V)

12.5-83

Max. efficiency, (%)

99.5

Surge category

II

Maximum output current, (A)

15

Maximum output voltage, (V)

80

Standby output voltage, (V)

1

Input / output connector type

MC4

Maximum allowed system voltage, (V)

1000

Temperature range, (ºC)

-40+85

Output cable length, (m)

1.2

Ingress protection

IP68

Dimensions W×L×H, (mm)

129 x 162 x 59

Weight, (g)

1064

Read more

Published on 2026/10/11

Description

SolarEdge P505 power optimizer is a specialized device designed to increase the output of photovoltaic panels. The optimizer tracks the maximum power point, increasing the energy output from photo modules by 25%. Another function of the optimizers is to monitor the photovoltaic system, collecting and transmitting data for monitoring. The device is installed on each panel or on two panels – this allows detailed control of each panel's production individually. The optimizers are equipped with the SafeDC feature, which automatically disconnects the DC voltage from the modules in case the grid power is lost or the inverter is turned off. Optimizers are compatible with c-Si and all thin-film photo-modules.

Main advantages of SolarEdge power optimizers:

-
Mitigates all losses related to module mismatch, from manufacturing tolerance to partial shading;

-
reduces system cost (50% fewer cables, fuses, and combiner boxes);

-
can be used with two photovoltaic modules connected in series or parallel (optimizer P600, P700);

-
flexible design system for maximum use of space;

-
quick installation with a single bolt;

-
module-level voltage shutdown for safety during installation;

-
module-level energy optimization;

-
high efficiency (99.5% maximum efficiency, 98.8% weighted efficiency);

-
designed to operate in extreme environmental conditions;

-
real-time performance measurements;

-
optimize module-level voltage increasing energy production by 25%;

-
allows mounting solar panels in locations with different solar insolation during the day;

-
SolarEdge power optimizers are compatible with c-Si and thin-film modules and carry a 25-year warranty.

Important!

-
The module's rated power at STC must not exceed the optimizer's "Rated DC input power." Modules with a power tolerance up to +5% are allowed.

-
For other connector types, contact SolarEdge

-
For the dual version for parallel connection of two modules use P485. When there is an odd number of photovoltaic modules in a string, it is supported to install one dual-version P485 power optimizer connected to a single photovoltaic module. When connecting one module, seal the unused input connectors with the pair of seals included in the delivery kit.

-
For ambient temperature above +70°C/+158°F a power derating applies. For more information refer to the temperature derating technical note.

-
Mixing P404/P485/P505/P601 with P370/P401/P500 in one string is not allowed

-
P370/P401/P500 cannot be used with the three-phase inverter SE3K (available in some countries; refer to the SE3K-SE10K three-phase inverter datasheet table)

-
Exactly 10 when using SE3K-RW010BNN4

-
If the inverters' AC rated power ≤ the largest rated power over time, the largest power over time may reach the inverters' maximum DC input power. See: https://www.solaredge.com/sites/default /files/se-power-optimizer-single-string-design-application-note.pdf

-
For 230/400 V network: up to 13,500 W per string is allowed if the maximum power difference between each limb is 2,000 W.

-
For 277/480 V network: up to 15,000 W per string is allowed if the maximum power difference between each limb is 2,000 W.

Technical specifications:

Power optimizer

SolarEdge P505

Rated module power compatible with the model, (W)

up to 505

Maximum input current, (A)

14

Maximum input voltage, (V)

83

MPPT voltage range, (V)

12.5-83

Max. efficiency, (%)

99.5

Surge category

II

Maximum output current, (A)

15

Maximum output voltage, (V)

80

Standby output voltage, (V)

1

Input / output connector type

MC4

Maximum allowed system voltage, (V)

1000

Temperature range, (ºC)

-40+85

Output cable length, (m)

1.2

Ingress protection

IP68

Dimensions W×L×H, (mm)

129 x 162 x 59

Weight, (g)

1064

    Attributes
Related listings in your area
How far is it? Show listings in my area
Show only listings that are km distanced Show listings

Contact the seller

User is offline
  • 538 active listings
  • Company
  • Registered for Sunday
  • Київ, Київська область, Україна
Call