Hot water storage tank from black steel TEPLOBAK VTA-1-1500 (upper heat exchanger 5.70 m²)

Hot water storage tank from black steel TEPLOBAK VTA-1-1500 (upper heat exchanger 5.70 m²)

132,412 ₴
Other
Sunday 11:56
Україна
вул. Стеценка, 14/44
32 views
Published 4 days ago by Solar-Tech
132,412 ₴
In Other category
вул. Стеценка, 14/44, Київ, Україна
Get directions →
32 item views

Buffer tank made of black steel VTA-1 is equipped with two heat exchangers.

In the lower part a heat exchanger is installed, and in the upper part a stainless steel domestic hot water heat exchanger for producing hot water for household needs.

The main distinguishing feature of this model is the ability to connect a large number of heat energy sources, which use both fossil fuels for energy generation (gas, solid fuel boilers) and alternative energy sources (solar collectors, heat pumps, electric boilers).

The combination of multiple energy sources increases the efficiency of both the heating system itself and each individual energy source by using the energy source when it is most effective and economical.

The model is available in volumes from 400 to 2000 L.

Features:

-

DHW heat exchanger made of smooth stainless tubing

-

Ability to connect any heat generators

-

Possibility to connect an electric heating element (TEN)

-

Volume 400-2000 liters

-

Possibility to manufacture any configuration per customer request

Technical specifications:

Nominal volume, L

1500

Maximum working pressure, bar

3

Maximum working pressure of the heat exchanger, bar

10

Working pressure on the heating circuit side, bar

6

Maximum operating temperature, °C

95

Heat exchanger area TO1, m2

2.3

Internal volume of heat exchanger TO1, L

18

Heat exchanger area TO2, m2

5.7

Internal volume of heat exchanger TO2, L

52

Inner tank material

black steel

Insulation

optional on request

Dimensions (HxØDxØd cm. see drawing), mm

2150х1200х1000

Net weight, kg

-

Price and types of thermal insulation, €

PL/PVC

PU/PVC

PL/ABS

PS/ABS

285

350

400

455

-
PL/PVC — polyester insulation 100 mm thick in a PVC fabric jacket with a zipper, a budget option providing the heat retention function.

-
PU/PVC — insulation of flexible polyurethane foam 90 mm thick in a PVC fabric jacket with straps or a zipper.

-
PL/ABS — polyester insulation 100 mm thick in an ABS plastic jacket with plastic locks. Effective insulation + display design.

-
PS/ABS — rigid 100 mm insulation made of graphite-enhanced expanded polystyrene in an ABS plastic jacket. Premium-class insulation – meets all requirements of the ErP 2009/125/EC directive (classes B and C, depending on tank volume)

Read more

Published on 2026/10/11

Description

Buffer tank made of black steel VTA-1 is equipped with two heat exchangers.

In the lower part a heat exchanger is installed, and in the upper part a stainless steel domestic hot water heat exchanger for producing hot water for household needs.

The main distinguishing feature of this model is the ability to connect a large number of heat energy sources, which use both fossil fuels for energy generation (gas, solid fuel boilers) and alternative energy sources (solar collectors, heat pumps, electric boilers).

The combination of multiple energy sources increases the efficiency of both the heating system itself and each individual energy source by using the energy source when it is most effective and economical.

The model is available in volumes from 400 to 2000 L.

Features:

-

DHW heat exchanger made of smooth stainless tubing

-

Ability to connect any heat generators

-

Possibility to connect an electric heating element (TEN)

-

Volume 400-2000 liters

-

Possibility to manufacture any configuration per customer request

Technical specifications:

Nominal volume, L

1500

Maximum working pressure, bar

3

Maximum working pressure of the heat exchanger, bar

10

Working pressure on the heating circuit side, bar

6

Maximum operating temperature, °C

95

Heat exchanger area TO1, m2

2.3

Internal volume of heat exchanger TO1, L

18

Heat exchanger area TO2, m2

5.7

Internal volume of heat exchanger TO2, L

52

Inner tank material

black steel

Insulation

optional on request

Dimensions (HxØDxØd cm. see drawing), mm

2150х1200х1000

Net weight, kg

-

Price and types of thermal insulation, €

PL/PVC

PU/PVC

PL/ABS

PS/ABS

285

350

400

455

-
PL/PVC — polyester insulation 100 mm thick in a PVC fabric jacket with a zipper, a budget option providing the heat retention function.

-
PU/PVC — insulation of flexible polyurethane foam 90 mm thick in a PVC fabric jacket with straps or a zipper.

-
PL/ABS — polyester insulation 100 mm thick in an ABS plastic jacket with plastic locks. Effective insulation + display design.

-
PS/ABS — rigid 100 mm insulation made of graphite-enhanced expanded polystyrene in an ABS plastic jacket. Premium-class insulation – meets all requirements of the ErP 2009/125/EC directive (classes B and C, depending on tank volume)

    Attributes
Related listings in your area
How far is it? Show listings in my area
Show only listings that are km distanced Show listings

Contact the seller

User is offline
  • 538 active listings
  • Company
  • Registered for Sunday
  • Київ, Київська область, Україна
Call