Only for individual electricity consumers (electrical appliances)
The inverter generator KS 4000iE S ATS has a built-in ATS unit and can operate in both manual and automatic modes.
The OFF-RUN rotary switch on the right side of the generator combines the fuel valve, the internal 12 V power switch and the ignition switch. When the generator is not in use, it should remain in the OFF position so that the generator’s lithium battery does not discharge. The generator is supplied with the battery disconnected and it must be connected under the left cover before first use. The battery is charged by the internal charging module while the generator is running, or when there is 230 V voltage on the MAINS INPUT (regardless of the rotary switch position).
The voltage on MAINS INPUT 230V is monitored as soon as the rotary switch is set to RUN and the ATS SWITCH is set to ON. If the 230 V voltage on the MAINS INPUT disappears, the ATS controller starts the generator and switches the 230 V sockets to power from the inverter module.
KS 4000iE S ATS has 2 x 230 V sockets that are connected differently depending on the generator version.
Only for individual electricity consumers (electrical appliances):
Both 230 V sockets are active when running from MAINS INPUT as well as when running from the generator.
When running from MAINS INPUT, the two 230 V sockets have the same system (IT, TN, TT) that comes in on the MAINS INPUT. The generator must be earthed in TT and TN systems with a copper cable of 6-10 mm² (depending on local regulations), connecting its earth terminal screw to the same earth bus to which the 230 V MAINS INPUT supply is earthed.
The two sockets after switching to generator power have an IT system with an isolated neutral. Rules and protective measures for IT systems must be observed.
With this generator variant it is only possible to provide direct backup power to electricity consumers that can operate in both TN and IT networks. Powering an entire house in automatic mode is not possible!
If you wish to automatically power individual electricity consumers or their groups (house, office, etc.) in a TN system with a grounded neutral conductor, we recommend using Version 2 of the KS 4000iE S ATS generator Version 2
DISCLAIMER:
This informational material is intended to familiarize you with the generator’s functions and possible applications and may be considered only as recommendations which must be adapted to the circumstances and conditions during installation. The installation itself must be carried out by qualified personnel in compliance with all applicable local installation standards and regulations. We are not responsible for incorrect installations and their consequences.
Only for individual electricity consumers (electrical appliances)
The inverter generator KS 4000iE S ATS has a built-in ATS unit and can operate in both manual and automatic modes.
The OFF-RUN rotary switch on the right side of the generator combines the fuel valve, the internal 12 V power switch and the ignition switch. When the generator is not in use, it should remain in the OFF position so that the generator’s lithium battery does not discharge. The generator is supplied with the battery disconnected and it must be connected under the left cover before first use. The battery is charged by the internal charging module while the generator is running, or when there is 230 V voltage on the MAINS INPUT (regardless of the rotary switch position).
The voltage on MAINS INPUT 230V is monitored as soon as the rotary switch is set to RUN and the ATS SWITCH is set to ON. If the 230 V voltage on the MAINS INPUT disappears, the ATS controller starts the generator and switches the 230 V sockets to power from the inverter module.
KS 4000iE S ATS has 2 x 230 V sockets that are connected differently depending on the generator version.
Only for individual electricity consumers (electrical appliances):
Both 230 V sockets are active when running from MAINS INPUT as well as when running from the generator.
When running from MAINS INPUT, the two 230 V sockets have the same system (IT, TN, TT) that comes in on the MAINS INPUT. The generator must be earthed in TT and TN systems with a copper cable of 6-10 mm² (depending on local regulations), connecting its earth terminal screw to the same earth bus to which the 230 V MAINS INPUT supply is earthed.
The two sockets after switching to generator power have an IT system with an isolated neutral. Rules and protective measures for IT systems must be observed.
With this generator variant it is only possible to provide direct backup power to electricity consumers that can operate in both TN and IT networks. Powering an entire house in automatic mode is not possible!
If you wish to automatically power individual electricity consumers or their groups (house, office, etc.) in a TN system with a grounded neutral conductor, we recommend using Version 2 of the KS 4000iE S ATS generator Version 2
DISCLAIMER:
This informational material is intended to familiarize you with the generator’s functions and possible applications and may be considered only as recommendations which must be adapted to the circumstances and conditions during installation. The installation itself must be carried out by qualified personnel in compliance with all applicable local installation standards and regulations. We are not responsible for incorrect installations and their consequences.
Attributes
Related listings in your area
How far is it?Show listings in my area
Show only listings that arekm distancedShow listings
Moisture-resistant and dustproof cover for all gasoline generators of the KS 2900, KS 3000 series. Protects from rain, snow, frost, sun and wind Resistant to ultraviolet (UV) radiation Resistant to acid rain and bird droppings Protects from dust and dirt.
The KS 2100i S gasoline inverter generator of the German brand Könner & Söhnen in a soundproof housing is a convenient and compact power source with a low noise level. The key feature of this model is that it produces electric current with a true sine wave. An economy mode allows fuel consumption to be reduced by up to 50% at light loads by lowering the ...
With the KS PU1 parallel connection module from the "Könner & Söhnen" brand, you have the ability to increase the total output power of generators by connecting two inverter generators together.When two models of generators are connected in parallel, you can obtain an output power equal to the sum of the rated powers of those models.When generators are c...
The portable hybrid power station KS 5200PS from Könner & Söhnen® is not just a charging station, but the smart core of your energy independence, a high-tech 3-in-1 solution. This hub with a multifunctional hybrid power station at its center combines all available energy sources – the grid, the sun, an external 5.12 kWh battery or a DC generator – and ma...
The portable hybrid power station KS 3000PS from Könner & Söhnen® is not just a charging station, but the smart core of your energy independence, a high-tech 3-in-1 solution. This hub with a multifunctional hybrid power station at its center combines all available energy sources – the grid, the sun, an external 3.2 kWh battery, or a DC generator – and au...
The KS 24VM DC direct voltage generator of the German brand Könner & Söhnen® with a rated current of 60A and an operating voltage of 24–27.5V is a reliable and powerful device designed as a backup charger for charging 24V batteries. Thanks to its high performance and characteristics, this generator will become an indispensable assistant in cases of emerg...
24–27V direct current generator with a maximum current of 60A from the German brand Könner & Söhnen® – designed as a backup charging device for charging 24V batteries. The generator does not require any converters to obtain a 24V DC voltage, which significantly increases efficiency and eliminates undesirable effects typical when using AC generators in 24...
The inverter generator KS 9500iE S ATSR of the German brand Könner & Söhnen provides a peak power of 9.5 kW and a nominal power of 9.0 kW, making it a versatile solution for backup power for a home, professional construction sites, or outdoor events. Thanks to inverter technology with a true sine wave, it safely powers laptops, televisions, and other sen...
The KS 48VGS-DC DC voltage generator version 50-55V of the German brand Könner & Söhnen is designedThe generator runs on gasoline and gas, making it a versatile solution for providing autonomous power in various conditions and allowing the user to choose the more available or economical fuel depending on the situation.The generator is suitable for rechar...
The KS 48VS-DC constant voltage generator version 50-55V from the German brand Könner & Söhnen is designed as a backup charger for charging batteries whose operating voltage range includes 50-55V.The generator is suitable for recharging batteries in the field of ensuring energy independence for private households, for off-grid, solar, wind, telecommunica...
The inverter generator KSB 32i S provides a stable continuous rated power of 3.0 kW, which guarantees reliable operation of household appliances, tools, and sensitive electronics. With a maximum power of 3.2 kW it has extra headroom for starting loads, making it suitable for more demanding tasks.One of the key advantages is the exceptional power-to-weight ra...
KS 3000iG S is a compact and efficient inverter generator designed forthose who need reliable power without excessive noise. Providing a peakpower of 3.3 kW and a rated 3.0 kW when running on petrol (power is reduced by 10% when running on gas), it has sufficient reserve to power essentialappliances during a power outage, tools on construction sitesor equipm...
Inverter technology with a diesel engine in a soundproof casing is a market innovation, combining stable and clean electricity supply, fuel efficiency, and quiet operation. The Könner & Söhnen® KS 6500iDE S ATSR HEAVY DUTY diesel inverter generator, with 6.5 kW max and 6.0 kW rated output, is a reliable power source for a wide range of needs such as medi...
Advanced variant of the LP-M-60-H / MN-340 HALF CELL 9BB series – a new product from the Japanese brand "Lepton". High-performance monocrystalline SPLIT-type module. The power-generating device is manufactured using Half Cell technology: instead of 60 full-size cells it has 120 half-sized photovoltaic cells. Thanks to shortened current-carrying busbars and a...