Hot water storage tank from black steel TEPLOBAK VTA-1-750 (upper heat exchanger 1.55 m²)

Hot water storage tank from black steel TEPLOBAK VTA-1-750 (upper heat exchanger 1.55 m²)

58,075 ₴
Other
Sunday 11:55
Україна
вул. Стеценка, 14/44
20 views
Published 4 days ago by Solar-Tech
58,075 ₴
In Other category
вул. Стеценка, 14/44, Київ, Україна
Get directions →
20 item views

Buffer tank made of black steel VTA-1 is equipped with two heat exchangers.

There is a heat exchanger installed in the lower part, and in the upper part a hot water supply system heat exchanger made of stainless steel for producing hot water for household needs.

The main distinguishing feature of this model is the ability to connect a large number of heat energy sources that use both fossil fuel (gas, solid fuel boilers) and alternative energy sources (solar collectors, heat pumps, electric boilers) to obtain energy.

The combination of several energy sources increases the efficiency of both the heating system itself and an individual energy source by using the energy source at the time when it is most effective and economical.

The model is available in volumes from 400 to 2000 L.

Features:

-

Domestic hot water heat exchanger made of smooth stainless tube

-

Ability to connect any heat generators

-

Ability to connect an electric heating element (TEN)

-

Volume 400-2000 liters

-

Ability to manufacture any configuration per customer specification

Technical specifications:

Nominal volume, L

750

Maximum working pressure, bar

3

Maximum working pressure of the heat exchanger, bar

10

Working pressure on the heating circuit side, bar

6

Maximum operating temperature, ºC

95

Heat exchanger TO1 area, m2

1.5

Internal volume of heat exchanger TO1, L

10

Heat exchanger TO2 area, m2

1.55

Internal volume of heat exchanger TO2, L

11

Inner tank material

black steel

Insulation

optional on request

Dimensions (HxØDxØd see drawing), mm

2010х950х750

Net weight, kg

-

Price and types of thermal insulation, €

PL/PVC

PU/PVC

PL/ABS

PS/ABS

190

260

280

320

-
PL/PVC — polyester insulation 100 mm thick in a PVC fabric cover with a zipper, a budget option providing heat retention function.

-
PU/PVC — elastic polyurethane foam insulation 90 mm thick in a PVC fabric cover with straps or a zipper.

-
PL/ABS — polyester insulation 100 mm thick in an ABS plastic cover with plastic locks. Effective insulation + display design

-
PS/ABS — rigid 100 mm insulation made of graphite-expanded polystyrene in an ABS plastic cover. Premium-class insulation – meets all requirements of the ErP 2009/125/EC directive (classes B and C, depending on tank volume)

Read more

Published on 2026/10/11

Description

Buffer tank made of black steel VTA-1 is equipped with two heat exchangers.

There is a heat exchanger installed in the lower part, and in the upper part a hot water supply system heat exchanger made of stainless steel for producing hot water for household needs.

The main distinguishing feature of this model is the ability to connect a large number of heat energy sources that use both fossil fuel (gas, solid fuel boilers) and alternative energy sources (solar collectors, heat pumps, electric boilers) to obtain energy.

The combination of several energy sources increases the efficiency of both the heating system itself and an individual energy source by using the energy source at the time when it is most effective and economical.

The model is available in volumes from 400 to 2000 L.

Features:

-

Domestic hot water heat exchanger made of smooth stainless tube

-

Ability to connect any heat generators

-

Ability to connect an electric heating element (TEN)

-

Volume 400-2000 liters

-

Ability to manufacture any configuration per customer specification

Technical specifications:

Nominal volume, L

750

Maximum working pressure, bar

3

Maximum working pressure of the heat exchanger, bar

10

Working pressure on the heating circuit side, bar

6

Maximum operating temperature, ºC

95

Heat exchanger TO1 area, m2

1.5

Internal volume of heat exchanger TO1, L

10

Heat exchanger TO2 area, m2

1.55

Internal volume of heat exchanger TO2, L

11

Inner tank material

black steel

Insulation

optional on request

Dimensions (HxØDxØd see drawing), mm

2010х950х750

Net weight, kg

-

Price and types of thermal insulation, €

PL/PVC

PU/PVC

PL/ABS

PS/ABS

190

260

280

320

-
PL/PVC — polyester insulation 100 mm thick in a PVC fabric cover with a zipper, a budget option providing heat retention function.

-
PU/PVC — elastic polyurethane foam insulation 90 mm thick in a PVC fabric cover with straps or a zipper.

-
PL/ABS — polyester insulation 100 mm thick in an ABS plastic cover with plastic locks. Effective insulation + display design

-
PS/ABS — rigid 100 mm insulation made of graphite-expanded polystyrene in an ABS plastic cover. Premium-class insulation – meets all requirements of the ErP 2009/125/EC directive (classes B and C, depending on tank volume)

    Attributes
Related listings in your area
How far is it? Show listings in my area